FNPM – Magnetic drive pump in plastic
Technical Data
Design
Horizontal centrifugal pump
Impeller
Closed
Temperature
-40 °C to 190 °C (-40 °F to 374 °F)
Material
Plastics
Delivery rate
Qmax. = 350 m3/h
Nominal pressure
up to 16 bar
Size
DN 25 - DN 125
Delivery head
Hmax. = 100 m (328 ft)
Aggressive, especially toxic, highly flammable, explosive or foul smelling media. In general all liquids that must not get into the atmosphere during the pumping process.
- Chlor-Alkali Electrolysis
- Sulphuric acid
- Nitric acid
- Hydrochlorid acid
- Organic solvents
Norm
ISO 5199, ISO 15783, ISO 2858, EN 22858
Type
horizontal, single-stage
Construction
back-pull-out design according to ISO 2858
Casing design
Single or double volute casing
Impeller
Closed
Bearing lubrication
Lifetime grease lubrication
Sleeve bearing lubrication
By pumping medium or external lubrication
Installation versions
Base frame welded or base plate cast
-20°C to 60°C (-4 °F to 140 °F)
Solid content limit value
approx. 3 %
Flange motor design (Type FNPMF)
Drain of volute casing
Flange connections according to international standards
Leakage monitoring
Storage and priming tank
Pump accessories
Perfluoralkoxi PFA
Polytetrafluorethylene PTFE